Waterproof Coatings & Liquid Membranes
Whether you need a high-elongation basement membrane or a vehicle-rated parking deck system, CHEMPU provides liquid-applied waterproof coating systems that survive movement, weather and traffic—from a single bathroom shower to a full roof restoration. Engineered with solvent-free polyurethanes, high-performance MS polymers, and reflective elastomeric acrylics, our factory formulations deliver durable monolithic protection across commercial, industrial, and civil infrastructure projects worldwide.
Comprehensive Waterproofing Coating Capabilities & Production Scale
As an established chemical synthesis manufacturer, CHEMPU integrates raw polymer compounding with precision automated filling to deliver high-performance waterproof coatings. Our coating and waterproofing technologies bridge structural movement gaps, endure permanent standing water, and protect critical substrates against severe weathering.
In-house synthesis spanning single-component polyurethane (high-elastic & high-tensile), hybrid MS polymer, waterborne elastomeric acrylic, and heavy vehicle-rated aromatic traffic deck membranes.
Ultra-low VOC and 100% solvent-free moisture-cure formulations that eliminate shrinkage, surface pinholing, and toxic gassing during sensitive indoor, basement, and shower installations.
Sealed industrial plastic pails (5 kg & 18 kg), heavy-duty lithographed steel pails (20 kg), and 230 kg bulk steel drums for large-scale airless spray applications and containerized export.
Standard Slate Grey, Brilliant White, Jet Black, and Oxide Green with full RAL color matching upon request. Custom thixotropic viscosity tailored for roller, squeegee, or high-pressure spray.
End-to-end contract toll blending, multilingual private label printing, customized cure velocity for cold or tropical climates, and full technical compliance support for international distributors.
Audited under ISO 9001:2015 quality standards with full compliance testing against ASTM C836, ASTM D412, ASTM D4541, and European CE/RoHS safety and environmental standards.
Master Specification Comparison: 4 Flagship Formulations
Compare verified laboratory properties, ASTM test data, and application profiles across CHEMPU’s four core chemical systems to select the exact membrane for your engineering specification.
| Technical Property / Standard | PU WP-001 High-Elastic Membrane | PU XYT-P101 Traffic-Bearing Deck | MS XYT-S001 Shower & Exposed Hybrid | Acrylic WA-100 Elastomeric Cool Roof |
|---|---|---|---|---|
| Base ChemistryPolymer Backbone | 1-Component Polyurethane (Moisture-Cure) | 1-Component Polyurethane (Heavy-Duty) | 1-Component Silane Modified Polymer (MS) | Waterborne Pure Elastomeric Acrylic |
| Solids Content by Weight (%)ASTM D1644 / ISO 3251 | ≥ 99.5% (High Solids) | ≥ 98.0% | 100% (Solvent-Free) | ≥ 68.0% |
| Elongation at Break (%)ASTM D412 / ISO 37 | ≥ 1000% | ≥ 450% | ≥ 400% | ≥ 320% |
| Tensile Strength (MPa)ASTM D412 | ≥ 2.5 MPa | ≥ 8.5 MPa | ≥ 3.0 MPa | ≥ 2.2 MPa |
| Shore HardnessASTM D2240 | Shore A 45 ± 5 | Shore A 60 ± 5 / Shore D 35 | Shore A 40 ± 5 | Shore A 55 ± 5 |
| Tack-Free Time25°C, 50% RH | 3 to 4 hours | 2 to 3 hours | 40 minutes (Rapid) | 1 to 2 hours |
| Full Mechanical Cure25°C, 50% RH | 24 hours | 48 hours (Light Traffic: 24h) | 24 hours | 24 to 48 hours |
| Service Temperature RangeContinuous Operation | -40°C to +120°C | -35°C to +100°C | -40°C to +90°C | -25°C to +80°C |
| UV Resistance & Exterior ExposureDirect Weathering (QUV 2000h) | Requires UV topcoat if permanently exposed | High abrasion resistance; UV stable | 10-Year Direct UV Stability (Non-yellowing) | Superior UV Reflection & Solar Index |
| Crack-Bridging AbilityASTM C1305 / EN 14891 | Passes > 3.0 mm dynamic crack | Passes > 2.0 mm crack | Passes > 2.0 mm crack | Passes > 1.5 mm crack |
| Substrate AdhesionASTM D4541 (Concrete) | ≥ 2.0 MPa (Concrete failure) | ≥ 3.0 MPa (Cohesive concrete failure) | ≥ 2.5 MPa (Glazed tile & damp concrete) | ≥ 1.8 MPa (Primed concrete & metal) |
| Application MethodContractor Tooling | Notched squeegee, roller, airless spray | Notched trowel, roller, aggregate broadcast | Brush, roller, notched trowel | Airless spray, heavy nap roller, brush |
| Standard Export PackagingPails & Bulk Drums | 20 kg steel pail, 230 kg drum | 20 kg steel pail, 230 kg drum | 20 kg white pail, 230 kg drum | 5 kg, 18 kg pail, 200 kg drum |
| Standard Color RangeVisual Identification | Grey, Black, White | Dark Grey, Traffic Black, Green | White, Light Grey, Clear | White (High SRI), Grey, Terracotta |
| Shelf Life (Unopened)5°C to 30°C Storage | 12 months | 12 months | 12 months | 18 months |
| Primary Intended ApplicationsJobsite Scope | Basements, underground subways, roofs, wet rooms | Parking decks, ramps, industrial plant floors | Showers, interior wet rooms, tile underlayment | Sloped roofs, metal roofs, exterior facades |
| Technical Data Sheet (TDS)Direct PDF Access | Download WP-001 TDS (PDF) | Download P101 TDS (PDF) | Download S001 TDS (PDF) | Download WA-100 TDS (PDF) |
Polyurethane Liquid Applied Waterproofing Membranes
A liquid applied waterproofing membrane engineered with reactive polyurethane polymers forms a tough, elastomeric rubber barrier directly onto complex concrete and masonry decks. Compared to conventional rolled bitumen sheets, liquid membrane waterproofing eliminates seams, cold joints, and torch hazards while offering extreme elongation for seismic and thermal substrate movement. CHEMPU’s polyurethane liquid applied waterproofing membranes span high-elastic formulations (WP-001) for underground waterproofing, high-tensile grades (XYT-P002) for rapid recoat cycles, and heavy-duty traffic systems (XYT-P101) for vehicular ramps. When specifying a waterproof liquid membrane, our single-component moisture-cure chemistry ensures seamless continuous adhesion with zero risk of delamination.

WP-001 Single-Component High-Elastic PU Liquid Membrane
Premier 1-part moisture-curing polyurethane coating delivering exceptional >1000% elongation at break for below-grade basements, tunnels, foundation slabs, and expansion joints.
- Elongation at Break: ≥ 1000%
- Tensile Strength: ≥ 2.5 MPa
- Solid Content: ≥ 99.5%

XYT-P002 High-Tensile Strength Polyurethane Coating
Rigid-flexible polyurethane liquid membrane engineered with 6.0 to 7.0 MPa high tensile strength for exposed roofs, inverted roof assemblies, and structural podium slabs.
- Tensile Strength: 6.0 – 7.0 MPa
- Elongation at Break: ≥ 500%
- Solid Content: ≥ 98.0%

XYT-P101 Vehicle-Rated Traffic Deck PU Membrane
High Shore A 60 abrasion-resistant polyurethane system designed to withstand heavy vehicular wheel traffic, aggregate broadcasting, and aggressive parking deck turning friction.
- Tensile Strength: ≥ 8.5 MPa
- Hardness: Shore A 60 ± 5
- Traffic Load: Heavy Vehicular Rated
MS Polymer Waterproof Coatings & Wet Area Shower Membranes
CHEMPU MS polymer waterproof coatings combine the elasticity of polyurethanes with the superior weathering, color stability, and non-hazardous handling of silicones. Featuring a 100% solvent-free, isocyanate-free chemical formulation, our MS polymer membranes cure rapidly within 40 minutes tack-free time and achieve 10-year direct UV exposure stability without chalking or yellowing. Engineered specifically for confined indoor wet areas, bathroom shower enclosures, balconies, and direct tiling applications, MS polymer provides exceptional primerless adhesion to damp concrete, fiber cement, and glazed tile substrates.

XYT-S001 MS Polymer Shower Membrane & Exposed Waterproof Coating
One-component silane-modified polymer liquid membrane offering 40-minute rapid tack-free cure, zero odor, 10-year UV stability, and outstanding direct bonding under ceramic tiles in luxury showers and wet rooms.
- Tack-Free Time: 40 Minutes (25°C)
- Elongation at Break: ≥ 400%
- UV Stability: 10 Years Direct Exposure
- Solvent & VOC: 0% Solvent / Zero Isocyanate

Why Contractors Specify CHEMPU MS Polymer for Wet Rooms
Standard polyurethanes emit strong solvent vapors and can bubble when applied over damp concrete or enclosed showers. CHEMPU XYT-S001 reacts with atmospheric moisture without off-gassing CO2 micro-bubbles, forming a dense monolithic water barrier that allows immediate tile adhesive mortar application within 24 hours.
Elastomeric Acrylic Waterproof Coatings & Cool Roof Systems
CHEMPU WA-100 is a single-component, waterborne pure acrylic elastomeric coating engineered for roof restoration, corrugated metal deck protection, and vertical building facades. Formulated with high-grade titanium dioxide and advanced cross-linking acrylic polymers, WA-100 cures into a vapor-permeable, highly flexible rubber membrane with over 320% elongation. Its high Solar Reflectance Index (SRI > 104) significantly lowers rooftop surface temperatures and building cooling loads, while its exceptional crack-bridging prevents water infiltration through exterior stucco, concrete, and aged asphalt roofing membranes.

WA-100 Elastomeric Acrylic Waterproof Roof & Wall Coating
High-build, waterborne acrylic elastomeric coating providing 320% elongation, high solar reflectance (cool roof), anti-fungal mold resistance, and vapor-breathable waterproofing for exterior building envelopes.
- Elongation at Break: ≥ 320%
- Solar Reflectance (SRI): > 104 (Brilliant White)
- Solids Content: ≥ 68.0%
- Packaging Sizes: 5 kg and 18 kg Pails

Key Benefits for Industrial Roof Restorations
Re-roofing an industrial complex can incur massive operational disruption and landfill expense. Applying CHEMPU WA-100 directly over existing aged modified bitumen, single-ply, or metal roofs seals standing seams, encapsulates fasteners, and adds 10 to 15 years of renewable leak protection at a fraction of replacement cost.
Engineered Waterproofing Solutions Across 5 Critical Industries
Every construction sector presents distinct hydrostatic, thermal, and mechanical challenges. CHEMPU supplies tested specification assemblies tailored to each building component.

Roof Systems
From concept to certified system, we deliver dry results for commercial flat roofs, corrugated metal roofs, and inverted assemblies.
roof coating systems from CHEMPU
Deck Systems
From concept to certified system, we deliver dry results for exterior plywood decks, concrete podiums, and pedestrian walkways.
deck coating systems for wood and concrete
Balcony & Terrace
From concept to certified system, we deliver dry results for residential balconies, cantilevered terraces, and perimeter drip edges.
balcony waterproofing system range
Traffic Decks
From concept to certified system, we deliver dry results for multi-story parking garages, loading bays, and heavy vehicular ramps.
vehicle-rated traffic coating systems
Basement Structures
From concept to certified system, we deliver dry results for below-grade foundations, elevator pits, retaining walls, and civil subways.
below-grade foundation waterproofingLatest Field Guides & Specification Insights
Explore in-depth technical analysis written by CHEMPU chemical application engineers covering polymer selection, substrate preparation SOPs, and troubleshooting.
Best Roof Waterproofing Coating Systems: PU vs Acrylic vs Silicone
An exhaustive comparative guide examining elongation retention, ponding water resistance, solar reflectance index, and lifecycle costs for commercial flat roof restorations.
best roof waterproofing coating guideIs Polyurethane Waterproof? Molecular Structure & Hydrostatic Limits
Chemical breakdown of 1-part vs 2-part polyurethane liquid applied membranes, moisture-curing reaction kinetics, and how to prevent bubbling during damp weather installations.
is polyurethane waterproof explainedHow to Waterproof a Bathroom: Step-by-Step Liquid Membrane SOP
Step-by-step contractor protocol for under-tile bathroom waterproofing using MS polymer, detailing corner bond breakers, pipe penetrations, and flood test procedures.
how to waterproof a bathroom guideFrequently Asked Questions: Waterproof Coatings
Immediate, definitive answers to technical specification, chemical compatibility, minimum order quantities, and OEM capabilities.