WA-100 Elastomeric Waterproofing Coating (Acrylic)
WA-100 is a high-solids, liquid applied elastomeric waterproofing membrane engineered with pure acrylic polymers for long-term weatherproofing of exterior walls, commercial roofs, and building facades. Delivering over 300% elongation, self-leveling thixotropy, and proven 34.28 g/m²·24h breathable vapor permeability, it forms a monolithic barrier that seals thermal cracks without blistering.
Vapor Permeable (34.28 g/m²·24h)
Self-Leveling & Crack-Bridging
Exterior Walls, Roofs & Facades
5kg & 18kg Heavy-Duty Pails
WA-100 Master Technical Specifications
Comprehensive physical properties, curing kinetics, adhesion metrics, and weathering durability tested in accordance with ASTM C836, ASTM D2370, and ISO international standards.
| Technical Parameter | Specification / Measured Value | Test Standard | Classification |
|---|---|---|---|
| Product Model | CHEMPU WA-100 Multi-Purpose Acrylic Coating | Factory TDS v1.02 | 1-Component |
| Chemical Polymer Base | 100% High-Grade Weather-Resistant Acrylic Polymer | Spectroscopic Analysis | Pure Acrylic |
| Carrier / Solvent System | Water-based, zero solvent, non-toxic, eco-friendly | ISO 11890-2 | Eco Water-Based |
| Standard Color | Solar Reflective Brilliant White (Customizable) | Visual / Hunter Lab | UV Reflective |
| Flow Ability & Rheology | Thixotropic Self-Leveling (roller, squeegee, airless spray) | ASTM D2196 | Self-Leveling |
| Solid Content (by weight) | ≥ 65.0% | ASTM D1644 / GB/T 16777 | High Solids |
| Elongation at Break | ≥ 300% (High elasticity dynamic crack bridging) | ASTM D2370 / GB/T 16777 | Elastomeric |
| Tensile Strength | ≥ 1.0 MPa | ASTM D2370 | Structural |
| Water Vapor Permeable Rate | 34.28 g / (m²·24h) (Breathable micro-porous membrane) | ASTM E96 (Wet Cup) | Breathable |
| Tack-Free Time (25°C, 50% RH) | < 4 Hours | ASTM C679 | Rapid Recoat |
| Initial Fully Cured Time | ≤ 8 Hours (Walkable protective layer) | ASTM C679 | Fast Cure |
| Complete Drying / Through-Cure | 2 to 3 Days at standard room conditions | Jobsite Verification | Through Cure |
| Artificial Weathering (UV Resistance) | No cracking, no blistering, no flaking (3,000h QUV test) | ASTM G154 / ISO 4892-3 | UV Proof |
| Anti-Fungal & Mildew Resistance | Rating 0 (Zero fungal growth on surface) | ASTM G21 | Anti-Fungal |
| Pollution Properties & Dirt Pickup | Non-polluting, low dirt pickup, easily washable | ASTM D3719 | Washable |
| Low Temperature Flexibility | No cracking bent over 10mm mandrel at -10°C | ASTM D522 | Flexible |
| Adhesion to Concrete & Masonry | ≥ 0.8 MPa (Cohesive substrate failure) | ASTM D4541 | High Adhesion |
| Adhesion to Primed Metal Roof | ≥ 1.2 MPa | ASTM D4541 | Metal Bond |
| Application Ambient Temperature | +5°C to +35°C | Jobsite Requirement | SOP Guard |
| Service Temperature Range | -25°C to +80°C | Thermal Cycling | All-Climate |
| Specific Gravity / Density | 1.35 ± 0.05 g/cm³ | ASTM D1475 | Standard |
| Solar Reflectance Index (SRI) | > 100 (Cool roof white formulation reduces roof heat) | ASTM E1980 | Cool Roof |
| Packaging Units | 5 kg Plastic Pail / 18 kg Commercial Heavy-Duty Pail | Standard Logistics | Export Pails |
| Shelf Life & Storage | 9 Months sealed at 5°C to 25°C, humidity <50% RH | TDS Specification | 9 Months |
Engineered Acrylic Base & Material Architecture
Unlike ordinary exterior house paint, WA-100 acrylic elastomeric waterproof coating is formulated with high-molecular cross-linked polymers and specialized additives to achieve dynamic flexibility and long-term solar resistance.
Pure Acrylic Resin Backbone
Formulated with 100% pure acrylic polymer emulsions with high glass transition stability. Resists severe UV radiation, acid rain, and photo-oxidative degradation for up to 15 years without chalking or hardening.
Anti-Fungal & Anti-Algae
Fortified with non-leaching broad-spectrum biocidal complexes that prevent black mold, fungal hyphae, and green algae growth. Keeps architectural facades and roof surfaces clean and reflective in high-humidity tropical climates.
Micro-Porous Breathability
Engineered with a selective micro-porous pore network that allows internal trapped water vapor to escape at 34.28 g/(m²·24h). Prevents vapor entrapment and blister formation while repelling liquid storm water.
Self-Leveling Rheology
Optimized with advanced thixotropic associative thickeners for effortless roller, brush, or airless spray application. Levels out pinholes and brush marks automatically to build a continuous, pinhole-free waterproof film.

Reinforced Monolithic Film Architecture
When combined with CHEMPU stitch-bonded polyester reinforcing fabric, WA-100 creates an elastomeric composite membrane that absorbs massive structural shear stresses and building settling movements.
With an elongation rate exceeding 300% and tensile strength of ≥1.0 MPa, the cross-linked film stays elastic down to -10°C, preventing hairline substrate cracks from telegraphing through decorative facade coatings.
Vapor Permeability & Application Thickness Calculations
Compare why breathable elastomeric systems prevent catastrophic exterior wall blistering, and determine exact material consumption across different project substrates.
Performance Case: Trapped Substrate Moisture Evaporation vs. Blistering Risk
Concrete, brickwork, and stucco masonry naturally absorb ground and atmospheric moisture. When direct sunlight heats exterior walls up to 60°C, trapped moisture vaporizes and generates high vapor pressure beneath waterproof coatings.
Vapor Permeability: < 2.0 g / (m²·24h) (Impermeable Vapor Barrier)
Vapor Pressure Accumulation: Solar heat drives moisture inward and creates up to 35 kPa hydrostatic vapor pressure under the membrane.
Failure Mode: Severe osmotic blistering, adhesive debonding, liquid water entrapment, and premature facade paint delamination within 12 to 18 months.
Vapor Permeability: 34.28 g / (m²·24h) (High Vapor Permeability)
Vapor Equilibrium: Micro-porous acrylic channels continuously release vapor into the open air as pressure rises, maintaining equilibrium.
Result: Zero blistering, dry masonry core, continuous liquid rain barrier, and permanent substrate adhesion exceeding 0.8 MPa.
Application Passes, Film Thickness & Material Consumption Schedule
| Application Target | Passes | Wet Film (WFT) | Dry Film (DFT) | Consumption (kg/m²) | Recoat Interval |
|---|---|---|---|---|---|
| Exterior Walls & Facades | 2 Thin Coats | 600 – 900 μm | 400 – 600 μm | 0.5 – 1.0 kg/m² | 2 – 4 Hours |
| Old/New Roof Waterproofing | 2 – 3 Cross Coats | 1,500 – 1,800 μm | 1,000 – 1,200 μm | 1.5 – 2.0 kg/m² | 4 – 6 Hours |
| Reinforced Joint / Gutter Details | 3 Coats + Mesh | 2,000 – 2,500 μm | 1,300 – 1,600 μm | 2.2 – 2.8 kg/m² | 4 – 6 Hours |
| Balconies & Ground Parapets | 2 Heavy Coats | 900 – 1,200 μm | 600 – 800 μm | 1.0 – 1.2 kg/m² | 3 – 5 Hours |
Waterproof Exterior Wall Coatings & Facade Restoration
As a versatile liquid applied elastomeric waterproofing membrane, WA-100 bridges the critical engineering gap between decorative architectural paint and heavy-duty industrial roofing membranes.
1. Exterior Walls & Facades
Permanent waterproof exterior wall coatings for concrete towers, stucco villas, autoclaved aerated concrete (AAC), and fiber cement boards. Prevents water penetration through wind-driven rains while letting walls breathe.
2. Commercial Roof Refurbishment
Direct application over aged metal roofing, modified bitumen, asphalt shingle, and concrete slabs without costly tear-off. Explore our full roof coating range for flat and metal roofs for high-traffic PU and hybrid alternatives.
3. Balconies, Terraces & Sills
Flexible waterproof protection for cantilevered balconies, bay window sills, parapet caps, and roof gutters subject to heavy rainwater pooling and temperature extremes.
4. Maintenance & Leak Sealing
Rapid leak repair over existing compromised membranes, flashing terminations, seam cracks, skylight perimeters, and HVAC duct roof penetrations.
5. Sprayed PU Foam Protection
Protective high-reflectance UV shield applied over on-site sprayed polyurethane foam (SPF) insulation, preventing foam solar degradation and bird pecking damage.
6. Architectural Color Finishing
Dual decorative and waterproofing functionality. Replaces conventional primer-paint-sealer multi-layer assemblies with one high-elasticity acrylic waterproofing system.
WA-100 Standard 2-Coat Cross-Application SOP
Follow our certified contractor application protocol to guarantee watertight integrity and ASTM C836 performance.
Substrate Inspection
Substrate must be structurally solid, dry, smooth, and free of oil, dust, or loose efflorescence. Repair spalls and grind sharp protrusions smooth.
Detail Pre-Sealing
Seal pipe penetrations, roof drains, gutters, and 90° Yin/Yang wall-to-floor junctions with polyurethane sealant and imbed non-woven reinforcement fabric.
First Thin Coat
Apply the first uniform coat in a horizontal direction using short-nap rollers or airless spray (0.4–0.5 mm wet thickness). Allow 2 to 4 hours to dry tack-free.
Second Cross Coat
Apply the second coat in a vertical direction strictly perpendicular to the first coat to guarantee zero pinholes. Total dry film thickness must be ≥0.8 mm.

Application Environmental Safeguards
Do not apply WA-100 when ambient or substrate temperatures fall below 5°C or exceed 35°C. Avoid application if precipitation, heavy fog, frost, or sandstorms are forecast within 24 hours.
Uncured material cleans up effortlessly with clean tap water. Once cured, the cross-linked acrylic membrane must be removed mechanically.
Color Tinting, Packaging & Private Label Services
CHEMPU operates automated high-shear mixing and tinting lines to supply distributors, major contractors, and private brand owners worldwide.
Architectural Color Matching
Standard production white features an SRI >100 cool roof rating. We custom-tint to RAL, Pantone, or customer master paint chips including light gray, terracotta, sandstone beige, and slate blue.
Export Packaging Options
Supplied in 5 kg retail pails (ideal for touch-ups and DIY renovation) and 18 kg contractor pails (optimized for palletized container loading). 200 kg bulk steel drums are available for industrial blending.
Private Label OEM/ODM
Complete OEM brand packaging support including bilingual IML (In-Mold Labeling), customized viscosities for tropical or sub-zero climates, and specialized anti-algae biocide packages.
Contractor Training & Factory Warranty Governance
We partner with international applicators to provide comprehensive jobsite quality control and multi-tiered warranty programs.
Contractor Video & SOP Training
Detailed step-by-step video SOPs, nozzle diameter recommendations for Graco/Titan airless spray equipment, and jobsite substrate preparation checklists.
Pull-Off Adhesion Verification
Standardized on-site test protocols using ASTM D4541 hydraulic dolly testers to verify concrete and metal roof adhesion prior to full-scale membrane application.
5 to 15-Year Factory Warranties
Material-only and system performance warranties backed by CHEMPU factory inspection certificates, third-party lab testing records, and project batch retention samples.
Frequently Asked Questions
Key engineering insights regarding elastomeric waterproofing technology, breathability, coverage rates, and substrate compatibility.
Request Factory-Direct Pricing & TDS
Direct response from CHEMPU waterproofing coating engineers within 2 business hours.